Cable transit frames and penetration sealing systems
Seal cable penetrations with our modular firestop solutions, designed to create water-, smoke- and gas-tight barriers in energy and industry projects both onshore and offshore
17 Products
Filter

- Description
- Transit frames for fitting firestop modules to seal cable/pipe penetrations – can be welded to steel bulkheads and decks
- Cable diameter - range
- 3 - 99 mm
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- -20 - 50 °C


- Description
- Round plug to seal against water and protect from fire in substation basements
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- -20 - 50 °C
- Product class
- Premium





- Description
- Transit frames for fitting modules to seal cable/pipe penetrations in concrete walls and floors
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Transit frames for fitting modules to seal existing cable/pipe penetrations in concrete walls and floors
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Transit frames for fitting modules to seal cables which penetrate switch cabinets
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Modules to seal cables/pipes within transit frames in potentially explosive atmospheres
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- -20 - 75 °C

- Description
- Filler modules for sealing unused space within transit frames in potentially explosive atmospheres
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- -20 - 75 °C

- Description
- Sleeves with flange for fitting plugs to seal round cable/pipe penetrations – for use with CFS-T RR and CFS-T RRS plug seals
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Modules to seal cables/pipes within a transit frame when high water- and gas-tightness and fire-resistance are required
- Approvals
- UL
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Modules with electromagnetic shielding properties to seal cables/pipes within a transit frame
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Filler modules for sealing unused space within transit frames when high water- and gas-tightness and fire-resistance are required
- Approvals
- UL
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Filler module with electromagnetic compatibility for sealing unused space within transit frames when high water- and gas-tightness and fire-resistance are required
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Plug seal for fitting modules to seal multiple cables/pipes in round penetrations
- Approvals
- UL
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Plug seal with electromagnetic compatibility for fitting modules to seal multiple cables/pipes in round penetrations
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Transit frames with 30-degree rounded edges for fitting modules to seal cable/pipe penetrations – can be welded in steel bulkheads and decks with high strain demand
- Number of frame rows
- 1
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- 50 - -20 °C

- Description
- Plug seal for sealing single cables/pipes in round penetrations
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- -20 - 50 °C

- Description
- Modules to seal cables within transit frames which penetrate switch cabinets
- Storage and transportation temperature range
- 5 - 25 °C
- Application temperature range
- -20 - 50 °C